TOOLS & REFERENCE


SAFRAIL™ Worksheet

Please submit the following worksheet for your SAFRAIL™ project.
  • Geographical Information

    CITY, STATE and NEAREST LARGE CITY are important because location may control code to be used for design. Standard SAFRAIL™ is UV coated.

    Platforms sheltered or inside other structures (INDOORS) will not require wind or snow loads. This answer may be apparent from specifications or drawings, but not so apparent from a telephone request for quote.

    Platforms outdoors and ABOVE GROUND (like on buildings) will have larger gust factors for wind conditions.

    Platforms in OPEN AND FLAT TERRAIN support HIGHER wind loads and LOWER snow loads. Platforms can be designed for worst case, but may be conservative and unnecessarily uneconomical.

  • Design Conditions and Loads

    Standard SAFRAIL™ will meet most codes for loading - OSHA, BOCA, UBC, etc. Other codes (for specific contract requirement, etc.) may require higher loads or have specific deflection requirements.

  • Please add any additional notes above:
  • Service and Quoting Requirements

    CORROSIVES AND TEMPERATURE may dictate EXTREN® requirements. EXTREN® SERIES may be specified. STANDARD COLOR or OTHER color is needed. HARDWARE will be bolts for structurals, grating clips and bolts, etc. SPECIFY as necessary.

  • (see Corrosion Guide for reference)
  • (°F for Ambient)
    Standard resin is polyester.
    All handrail is UV coated.
    All handrail is UV coated.
  • Accepted file types: pdf, jpg, gif, dwg.
    If a custom shape is desired from the Tube Shape section above, please upload your custom design using this file upload prompt.
    Standard SAFRAIL™ is a two-rail system with toe plate. Note that toe plate is not usually required where a platform or walkway is less than 4' above the adjacent floor or people cannot pass below (like SAFRAIL™ around a clarifier)..
  • or

    This is required to determine accurate pricing for quantity and type of material (base mount is most expensive).
    Post spacing determines the amount of material required per lineal foot.
  • Additional Notes and File Attachments

    When including drawings or layouts, be certain to note specifications such as overall lengths, locations of openings, sections to be removable, post spacing (if this has been set by the customer), straight rail or sloped (on concrete, steel or FRP stairs), gates, chained openings, etc.
  • Please add any additional notes above:
  • Additional Files

    For a firm price, submit drawings with this worksheet.
  • Accepted file types: pdf, jpg, gif, dwg.
  • Accepted file types: pdf, jpg, gif, dwg.
  • Accepted file types: pdf, jpg, gif, dwg.
  • Accepted file types: pdf, jpg, gif, dwg.